Settings
Flags
A set of flags are used to toggle certain functionality:
Flag |
Description |
Default |
Confirmed uplinks |
Confirmed uplinks are used for uplinks |
Off |
LED |
Enable the on board LED on uplink (always enabled for join) |
Off |
ADR |
Enable LoRaWAN Adaptive Data Rate |
On |
Continuous VOC |
Enable measuring the IAQ every 3 minutes for better calibration. This can be disabled to save power, but the VOC values may not be accurate anymore |
On |
General
Setting |
Description |
Default |
Measurement interval |
The interval of sensor measurements in seconds |
900 |
Send cycle |
This value is used to determine the number of measurements which are accumulated before sending under normal circumstances: Number of measurements = Send cycle - 1 |
0 |
Number of retransmissions |
The amount of time a LoRaWAN uplink is retransmitted if no ACK is received with confirmed downlinks |
2 |